zeros are displayed in the Surface Finish Symbol's after migrating with cmm

zeros are displayed in the Surface Finish Symbol's after migrating with cmm Here is the PR1937024 text:


  IR Number:	1937024

Problem Description:

Surface finish symbols do not migrate correctly

PS: looks the same as PR1931502 and PR1936453

I'm testing I-DEAS to NX migration for a new customer. They use surface finish symbols a lot in their I-DEAS drawings. In migration from I-DEAS to NX, all surface symbols get default values of "0" for values that were blank in the I-DEAS drawing. This is a regression in CMM/NX8.5.2. The same drawing that was migrated with CMM/NX7.5 showed surface symbols that did not have the problem.

The customer wants to have this fixed in CMM/NX8.5.2

=============================================================================

Customer NX Version: NX 8.5.2.3

Managed Mode: Yes

Tc Versions: n/a

Containing:


Part: Yes

Steps to Duplicate:

  1. Use CMM 8.5.2. to migrate the Ideas package see uploaded zipfile (IRnumber.pkg).

  2. Open the resulting drawing part file in NX Drafting.

Notice that zeros are displayed in a number of the Surface Finish Symbol's attribute fields, that were blank in the Ideas drawing.

Problem is part specific: No

Problem is OS specific: No Siemens PLM believes that the problem where surface finish symbols would not migrate correctly from I-deas to NX as documented in this PR, will be resolved by code changes made to the release of our product NX 10.0.3. PR 1969815 Product Information: Product: NX , Application: TRANSLATOR , Version: V8.0

Source: https://support.sw.siemens.com/en-US/knowledge-base/PL8019263 · retrieved 2026-10-02