Surface Finish Symbols do not migrate correctly from Ideas to NX via CMM

Surface Finish Symbols do not migrate correctly from Ideas to NX via CMM IR Number: 1931502

   Priority:	1

Business Urgency: No

   GTAC Urgency:	No

  PR Matrix:	6a,b

============================

Problem Description:

Surface Finish Symbols do not migrate correctly from Ideas to NX via CMM

=============================================================================

NX Versions: CMM 8.0.2 (with NX 8.0.3) and CMM 8.5.1 (with NX 8.5.1)

Managed Mode: No

Tc Versions: n/a

Containing:


Part: Support data contains an Ideas package file and the migrated NX data, CMM log files.

AVI: n/a

Syslog: n/a

Other Files: IR1931502.docx- Word document containing screen shots

Work Around: Display the Ideas drawing overlay in NX and modify the Surface Finish Symbol to have the correct values.

Steps to Duplicate:

  1. Use CMM Solo 8.0.2 (or 8.5.1) to migrate the Ideas package (export.pkg).

  2. Open the resulting drawing part file (123_0001.prt) in NX Drafting.

Notice that zeros are displayed in a number of the Surface Finish Symbol's attribute fields, that were blank in the Ideas drawing.

Problem is part specific: No

Problem is OS specific: No

Platform Information-

Problem is platform specific: No Platform:

Problem verified on the following platforms and OS versions:

Intel IV, Win7 64-bit Siemens PLM believes that the problem you reported where Surface Finish Symbols do not migrate correctly from Ideas to NX via CMM will be resolved by code changes made to the release of our product NX version 10.0.3.

PR 1931502 Product Information: Product: NX , Application: TRANSLATOR , Version: V8.0.2