NXKnowledge

Content Migration Manager > Knowledge base > I-deas

CMM Migration from I-DEAS to NX fails: System error during part import

CMM Migration from I-DEAS to NX fails: System error during part import 

Solution Use NX Load Options that comes with CMM product.  You may use two different load option files, one for NX, the other one for the CMM migration.  Follow instruction to incorporate CMM NX Load Options:

Make sure load_options.def from CMM config folder get used during migration: Add the following variable in file %CMM_BASE_DIR%\NXService\runnxservice.cmd:

UGII_LOAD_OPTIONS=%CMM_BASE_DIR%\config\load_options.def

adjust load_options.def as below if necessary: LoadOptions_LoadComponents: load_all_components LoadOptions_LoadFully: yes LoadOptions_LoadWAVE: YES LoadOptions_LoadWAVEParents: ALL LoadOptions_LoadSubstitution: allow_substitution LoadOptions_LoadLatest: NO LoadOptions_LoadFilters: load_no_components LoadOptions_LoadFailOption: dont_abort LoadOptions_ApplyAllLevels: NO LoadOptions_ActiveVariants: LoadOptions_GenerateMissingPFM: NO

Notes and References CMM I-deas

Hardware/Software Configuration Platform: INTEL OS: windows OS Version: 10-1909 Product: NX Application: CMM Version: V1953 Function: IDEAS

Ref: 001-10136164

Source: https://support.sw.siemens.com/en-US/knowledge-base/PL8576548 · retrieved 2026-10-02