NXKnowledge

Content Migration Manager > Knowledge base > Pro/ENGINEER and Creo

CMM Creo - Secondary geometry in view

CMM Creo - Secondary geometry in view

1 Call InformationThis call needs to be transferred to GTAC US and marked as PR so that the customer data can be made available to the Milford migration lab people working with CMM Pro/E tools.

Please close this call as PR and upload the supplied data to the PR data tool.

2 Symtom / Problem Description"Secondary geometry in view" is not migrated from Creo to NX. The functions and definitions are identical in Creo and NX.

Function description Creo:

  1. Start function "component display"

  2. Select component and select option "Phantom Trnsp"

  3. Select view

Function description NX:

  1. Start function "Secondary geometry in view"

  2. Select view

  3. Select component and select option "Secondary"

    (view settings / secondary geometrie - line settings)

2.1 Environment setup:

Environment Setup:

CMM Solo 1872.050

NX 1872 (Build 1500)

Creo Parametric 4.0 - M080

Windows10

2.2 ExpectationsWe expect "Secondary geometry in view" to be migrated from Creo to NX and editable.

2.3 Detail Information

Example 1 (MKR):

Creo: phantomtransparenz_nio.drw.9 (Folder: MKR\Creo)

NX: phantomtransparenz_nio_drw.9.prt (Folder: MKR\NX1872)

Example 2 (BLH):

Creo: 10056475.drw.1 (Folder: BLH/Creo)

NX: 10056475_drw.1.prt (Folder: BLH/NX1872)

Example 3 (BLH):

Creo: 10161112.drw.1 (Folder: BLH/Creo)

NX: 10161112_drw.1.prt (Folder: BLH/NX1872)

Question:

Do you need more drawings to investigate the issue?

2.4 Supporting DataFor more detailed information see PDF document within IR-Data Zipfile

.zip

FolderDescriptionTranslation Mode

BLH\Creo Creo files

BLH\NX1872 CMM Scratch from CMM/NX 1872 Series migration

MKR\Creo Creo files

MKR\NX1872 CMM Scratch from CMM/NX 1872 Series migration

2.5 PlattformWindows 10

2.6 Platform Specificno

2.7 Version Specificno The problem where "CMM Creo - Secondary geometry in view" has been investigated and the following has been found:This is being converted from a PR to an ER. PR 9591002 Product Information: Product: NX , Application: CMM , Version: V1872

Source: https://support.sw.siemens.com/en-US/knowledge-base/PL8478526 · retrieved 2026-10-02