Adulterate dimensions IR Number: 1985520

       Priority:	2

Business Urgency: No

   GTAC Urgency:	No

      PR Matrix:	Wrong Result

Problem Description:

================================

Dimension has incorrect Value after migration in NX.

Dimensions are changed after migration - from 2.5 to 248, or angle dimension from former 15° to 105°.

Application project: CMM PROE to NX

Drawing/Design: Drawing

Common/Part specific: common

Function: Horizontal and Angular Dimension

=============================================================================

Versions:

================================

NX: 8.5.3.3

Managed Mode: No

CMM: 8.5.2.186

1985520_6204983_logs.7z

1985520_IR-15.5 - Adulterate dimensions.docx.7z

Containing:

================================

1.) All PROE/NX parts and logs (syslog, cmm log, option file, etc.) located in: 1985520_6204983_logs.7z

2.) 1985520_IR-15.5 - Adulterate dimensions.docx

Work Around:

================================

Unknown

Steps to Duplicate:

================================

  1. CMM PROE drawing - Item ID: 6204983.drw

  2. Compare Detail PROE/NX View H_H/T-T on sheet 2

See "1985520_IR-15.5 - Adulterate dimensions.docx" for steps to duplicate and for clarification.

==> ERROR: Dimension has incorrect value

Expectation:

Dimension should have correct assignment as is in PROE

Problem is part specific: Unknown

Platform Information:

================================

Problem is platform specific: Unknown

Platform: Intel Win764-bit

Problem verified on the following platforms and OS versions:

Intel Win764-bit, NX 8.5.3.3 / CMM 8.5.2.186

This issue is currently open and under investigation. When the investigation completes, this article will be updated to include all of the pertinent information and conclusions. If you have further questions related to this article, or any article, please contact Support for assistance. PR 1985520 Product Information: Product: NX , Application: TRANSLATOR , Version: V8.5.2