Renaming Sheet cause NX to crash
Renaming Sheet cause NX to crash IR Number: 8391141
Priority: 1
Business Urgency: No
GTAC Urgency: No
PR Matrix: Fatal Error a,b
Problem Description:
================================
When a CMM migrated drawing was edited in NX, customer must rename the Sheet-Name to get rid of the former CATIA sheet name.
Because of this the CMM Overlay function cause NX to crash, after sheet name was renamed in the drawing.
Application/Function: Drafting / Drawing Migration - Overlay On/Off
Common/Part specific: Common
=============================================================================
Versions:
================================
NX 12.0.2.MP0
Managed Mode: No
Zip File Containing:
================================
Part: Yes
AVI: Yes
Syslog: no
Other Files: Yes
Steps to Duplicate:
================================
Open NX drawing "E00025873_01_s_E00025873-01-100282920.prt"
Select Drafting Tools
Turn Overlay On/Off
Rename Sheet-Name from "Sheet.1" to "Sheet1"
Turn Overlay On/Off
Error: NX will crash and must be closed from Task Manager
See movie.avi and images for details and how to reproduce.
==> ERROR: NX will continuous loop in an error sequence.
Work Around:
================================
Do not rename sheet
Expectation:
================================
Rename Sheet-Name should not corrupt Overlay function and cause NX to crash.
Problem is part specific:
================================
No
Platform Information:
================================
Problem is platform specific: no
Platform: Intel Win764-bit
Problem verified on the following platforms and OS versions:
Intel Win764-bit, NX12.0.2.MP0 and NX11.0.2.MPx
Additional Note
================================
For this customer it is necessary to rename all Sheet-Name to get rid of former CATIA sheet name when drawing is modified and saved the first time after migration from CATIA. This issue is currently open and under investigation. When the investigation completes, this article will be updated to include all of the pertinent information and conclusions. If you have further questions related to this article, or any article, please contact Support for assistance. PR 8391141 Product Information: Product: NX , Application: TRANSLATOR , Version: V12.0.2