Content Migration Manager > Knowledge base > CATIA
Catia Ordinate Dimension Issues
Catia Ordinate Dimension Issues CALL INFORMATION
This call needs to be transferred to GTAC US and marked as PR so that the customer data can be made available to the Milford migration lab people working with CMM Pro/E tools.
Please close this call as PR and upload the supplied data to the PR data tool.
SYMPTOM/PROBLEM
Environment setup:
Catia V5 R21
NX 10.0.1.4
CMM 10.0.1.077
In Catia we have drawings that uses Ordinate Dimensions where several dimensions are using the same base. This kind of dimension is equally available in NX.
During migration the ordinate dimension is split into several ordinate dimensions all with its own base.
Example 1: Drawing called "10028214"
o Catia: 2 ordinate dimensions with one base each
o NX: 6 ordinate dimensions with one base each
Catia
Abbildung 1: Catia_01.jpg
Abbildung 2: Catia_02.jpg
NX
Abbildung 3: NX_01.jpg
Abbildung 4: NX_02.jpg
CMM Migration Report
...\BG_01\Scratch\10028214.xml
Abbildung 5: CMM Migration Report - ordinate dimension baseline has discrepancy
CMM Migration Options
...\BG_01\Scratch\Muster1.opt.xml
Abbildung 6: CMM Drawing Options
Example 2: Drawing called "10013549"
CMM Migration Report
...\BG_01\Scratch\10013549.xml
Abbildung 7: CMM Migration Report - ordinate dimension issues
Example 3: Drawing called "10087284"
CMM Migration Report
...\BG_01\Scratch\10087284.xml
Abbildung 8: CMM Migration Report - more ordinate dimension issues
EXPECTATIONS:
Please submit this to the migration lab for further investigations.
CMM is expected to migrate ordinate dimensions with one single base as it is done in Catia and available in NX.
HOW TO REPRODUCE THE PROBELM:
Download the provided data file from GTAC (File:
o Migrate drawing with CMM using default cmmOptions (BREP mode for parts)
o Inspect the resulting NX drawing and CMM migration report
o CMM migration report shows issues with ordinate dimensions.
SUPPORTING DATA:
o Worddoc with description and screenshots
o Catia data
o Migrated NX data
o CMM Scratch Folders with logfiles
WORKAROUND:
~~~~~~~~~~~~~
nothing found
PLATFORM:
~~~~~~~~~~
Windows
PLATFORM SPECIFIC:
N/A
VERSION SPECIFIC:
N/A
ADDITIONAL INFORMATION:
N/A This issue is currently open and under investigation. When the investigation completes, this article will be updated to include all of the pertinent information and conclusions. If you have further questions related to this article, or any article, please contact Support for assistance. PR 7556087 Product Information: Product: NX , Application: CMM , Version: V10.0.1
Source: https://support.sw.siemens.com/en-US/knowledge-base/PL8058599 · retrieved 2026-10-02