NXKnowledge

Using Routing applications > Routing Electrical > Electrical routing navigators > The Create Connection Wizard

Stock step

Defines the properties of the connection stock.

Note: This step is not available unless Wire, Cable, or Shield is set as the Stock Type in the Connection Properties page.

Option Description
Select Wire / Select Cable / Select Shield Lets you select wire, cable, or shield stock from the Routing Part Library. This option is sensitive to the Stock Type setting on the Connection step.
Part Name NX Part Name of the stock.
Type Typically used to designate a wire insulation type.
Gauge The value of the wire gauge, if applicable.
Outer Diameter Diameter of the stock in work part units.
Part Number (part number for the stock)
Multiplier The value multiplied by the modeled length to calculate the Cut Length.
Offset The value added to the modeled length in order to calculate the Cut Length.
Class The wire class, if applicable, can be set to: Regular, Stowed, Twisted.
Color Color code of the stock.
Display Color The color used when displaying the modeled stock.

After clicking Finish from the Create Connection Wizard, NX copies the connection list contents of the topmost cable from the selected part to the work part. The name specified in the Create Connection Wizard is used for the target cable. If possible, NX reuses existing connectors and equipment based on the IDs of each. Otherwise, NX creates the connectors and equipment devices referenced by the connections under the cable. Routing and assignment information are not copied.

Summary step

The Summary reviews all parameters. This window displays a list of all specified options. You can use the Back button to edit any options. Choose Finish to create the connection when all information is correct.

How do I

  • Create a connection
  • Import a Cable Structure

Related topics

  • The Create Connection Wizard
  • Connection step
  • From Component step
  • To Component step
  • Intermediate Component step