NXKnowledge

Content Migration Manager > Knowledge base > I-deas

Datum attached to an ordinate dimension causes entire drawing to fail migration

Datum attached to an ordinate dimension causes entire drawing to fail migration Description of problem:

CMM fails with the following error if a drawing has a datum that is attached to an ordinate dimension:

      NXClient.importIDEASPart

          NXClient.importIDEASPart

*** 2014-11-18 10:21:03.345 System error during part import

          Failed to import XPK

          drawing: internal_7230805_dwg/A-Part1 exported 90%

*** 2014-11-18 10:21:03.346 Failed to create NX part

How to reproduce the problem:

This can be reproduced with generic data so the data is internal data.

  1.  Import the attached package ifle

  2.  Attempt to migrate the drawing with CMM and it will fail with the above mentioned errors.

 

Workaround:

Delete the A datum that is attached to the ordinate dimension line and then migrate the drawing.  

Platform(s) and version(s) tested on:

CMM 8.5 and CMM 9.0.2 (the data is for CMM 9.0.2)

Data or platform specific:

no

File type:

7z file containing a package file and the CMM log files

File location: See coordinator notepad

   

Other information:

none This issue is currently open and under investigation. When the investigation completes, this article will be updated to include all of the pertinent information and conclusions. If you have further questions related to this article, or any article, please contact Support for assistance. PR 7230805 Product Information: Product: NX , Application: TRANSLATOR , Version: V9.0.2