NXKnowledge

Content Migration Manager > Knowledge base > I-deas

CMM: wrong arrangement in assembly in use, after CMM migration, in TC Viewer

CMM: wrong arrangement in assembly in use, after CMM migration, in TC Viewer IR Number: 7742414

       Priority:	1

Business Urgency: No

   GTAC Urgency:	No

      PR Matrix:	Wrong Result a,b

Problem Description:

=============================================================================

After CMM Ideas to NX migration, the wrong arrangement get assigned in Teamcenter

=============================================================================

Versions:

=============================================================================

Managed Mode: Yes

NX: NX 10.0.3.5 MP5

TC: 10 (10.1.6(20160315.00)) 64-bit

TCII 10.1.11

I-deas: 6.4

CMM: 10.0.2

Containing:

=============================================================================

Part: yes

AVI: yes

Syslog: yes

Other Files: yes

Steps to Duplicate:

=============================================================================

Create Ideas Assembly with the follwing Structure and save the JT Files, or use the uploaded Ideas pkg file and Video.avi.

2016-06-17-000/A Assy

  • BOM View

  • Config

  • 2016-06-14-100/A SubAssy

    BOM View

    • Config A (in use)

    • Config B

  • 2016-06-14-101/A SubAssyPart

  • 2016-06-14-100/A SubAssy

    BOM View

    • Config A

    • Config B (in use)

  • 2016-06-14-101/A SubAssyPart

  • 2016-06-17-001/A Part1

Send the Assy in the Structure Manager, open the Graphics Panel and Load the whole structure

The Assembly looks exactly the same as in Ideas and use the corret arrangement in the SubAssy

migrate the 2016-06-17-000/A Assy with CMM

after the CMM migration send the Assy in the Structure Manager and load the whole structure again in the Graphics panel

The second SubAssy 2016-06-14-100/A SubAssy has the wrong Arrangement in use.

If you open the Assembly in NX it looks exactly the same as in Ideas, only the TC Viewer use the wrong arrangement.

Error: during CMM I-deas to NX migration, the incorrect arrangement was assigned.

Work Around: Unknown

Problem is part specific: Unknown

Platform Information:

=============================================================================

Problem is OS specific: No

Problem is platform specific: No

Platform: Intel Win764-bit

Problem verified on the following platforms and OS versions:

Intel Win764-bit, NX10.0.3.5 MP5/ TC10.1.3/CMM10.0.3

Additional Notes:

================================

If you open the Assembly in NX it looks exactly the same as in Ideas, only the TC Viewer use the wrong arrangement. This issue is currently open and under investigation. When the investigation completes, this article will be updated to include all of the pertinent information and conclusions. If you have further questions related to this article, or any article, please contact Support for assistance. PR 7742414 Product Information: Product: NX , Application: TRANSLATOR , Version: V10.0.3

Source: https://support.sw.siemens.com/en-US/knowledge-base/PL8068876 · retrieved 2026-10-02