Content Migration Manager > Knowledge base > I-deas
CMM 9 => Extrude Until Next not honored!
CMM 9 => Extrude Until Next not honored! IR Number: 7535163
Priority: 1
Business Urgency: No
GTAC Urgency: No
PR Matrix: Fatal Error
Problem Description:
================================
CMM - I-deas => Extrude Until Next not honored!
Customer employs CMM process to convert I-deas Data into NX. Common I-deas Parts use the option "Extrude Until Next" to cover design indent. But the resultant NX feature does not honor the option "Until Next" and the extrude command is performed through the entire NX part!
Furthermore this fatal failure is not recorded as an Error nor as a Warning in the CMM-Report which is unacceptable to the customer.
Feature: Extrude Until Next
Common/Part specific: common
Function: Feature History
=============================================================================
Versions:
================================
NX: 9.0.3.4.MP9
I-deas 6.4
CMM 9.0.3.rev1
Managed Mode: YES
Teamcenter 9.1.2.7
Containing:
================================
Part: Yes
AVI: n/a
Syslog: Yes
Other Files: Yes
Work Around:
================================
Unknown
Steps to Duplicate:
================================
Open Model File kirstin.mf1
Check-In part to Teamcenter
CMM Part "0494xxxx2_Beleuchtungsgehaeuse_1_Alu" to NX
Compare NX Extrude70 vs. I-deas Extrude(64)
See attached MS Word file for steps to duplicate and for clarification.
ERROR:
================================
The Extrude Option "Until Next" was not used; instead the entire part was cut!
Expectation:
================================
NX should create the Feature with the same options as it was in I-deas.
Customer expects an error message in the CMM Report when a Feature is not applied as expected and will differ from the original.
Problem is part specific: no
Platform: Intel Win764-bit
Problem verified on the following platforms and OS versions:
Intel Win764-bit, NX: 10.0.2.6.MP3, CMM 10.0.2.150, I-deas 6.4, Teamcenter 10.1.3
Additional Notes:
================================
The problem where "CMM 9 => Extrude Until Next not honored!" has been investigated and the following has been found.
Ideas to NX migration tool needs enhancement to honor extrude until next in all cases. PR 7535163 Product Information: Product: NX , Application: TRANSLATOR , Version: V9.0.3
Source: https://support.sw.siemens.com/en-US/knowledge-base/PL8058299 · retrieved 2026-10-02