Content Migration Manager > Knowledge base > CATIA
Bundle Segment in main assembly file not generated after CMM translation.
Bundle Segment in main assembly file not generated after CMM translation. IR Number: 1955104
Priority: 2
Business Urgency: No
GTAC Urgency: No
PR Matrix: WRONG_RESULT
Problem Description:
================================
In CMM version (8.0.2), the bundle segment was generating after
translation.
But in new CMM version (8.5.1.2), Bundle Segment in main assembly file not
generating.
Impact: Harness Migration will be affected with the missing bundle segment
data.
(Domain EE)
Application Project: PLM2015
Drawing/Design: Design
Common/Part specific: Common
Function: -
=============================================================================
Versions:
================================
NX 8.5.1.3
Managed Mode: No
CMM: v8.5.1.1.155
1955104_e6ce2214-204b-11e3-8294-c08a0d120286.zip Containing:
================================
HAV999540D000_Not Translating Bundle Segment.ppt
CATIA Parts in folder ..\Input\
CMM8.0.2 logs and parts in folder ..\CMM8.0.2
CMM8.5.1.2 logs and parts in folder ..\CMM8.5.1.2
Work Around:
================================
Unknown
Steps to Duplicate:
================================
See "HAV999540D000_Not Translating Bundle Segment.ppt" for steps to duplicate and for clarification.
Issue occurred after translating a CATProduct by CMM
==> ERROR: No error message
Expectation:
Bundle Segment in main assembly should be present after translation.
Problem is part specific: Unknown
Platform Information:
================================
Problem is platform specific: Unknown
Platform: Intel Win764-bit, NX8.5.1.3
Problem verified on the following platforms and OS versions:
Intel Win764-bit, NX8.5.1.3
Siemens PLM believes that the problem you reported where "Bundle Segment in main assembly file not generated after CMM translation." is resolved in CMM 852 and later release of our software.
PR 1955104 Product Information: Product: NX , Application: CMM , Version: V8.5.1