CMM Creo - Pattern Feature unsupportet for Assembly Cut 1 Symtom / Problem DescriptionPattern features are unsupported within Assembly Cut (assembly-part).
All feature (holes and threads) in the following examples are migrated as a single features.
We always use Feature Translation Mode = BrepMode, however, in "FeatureMode" we get the same result.
1.1 Migration Environment:Environment Setup 1:
CMM Solo 12.0.2.093
NX 12.0.2.9
Creo Parametric 4.0 - M080
Windows7
Environment Setup 1:
CMM Solo 1847.192
NX 1859
Creo Parametric 4.0 - M080
Windows10
1.2 ExpectationsSingle features are migrated as Assembly Cut, we expect the same for the feature pattern.
Then the bolt (b_31_din912) in the assembly can also be migrated with a "pattern component".
CMM Continous Release should be enhanced with support for Assembly Cut as pattern
1.3 Detail InformationExample simple" / Path: \example_simpleNX1847_Series...
Creo Data
Assembly Cut (assembly-part) = b_31_ubg1.asm.5
Part "Promote Body" = b_31_bg-t.prt.3
Pattern Feature Type = Dimension
1.4 Supporting DataFor more detailed information see PDF document within IR-Data Zipfile
FolderDescriptionTranslation Mode
example\Creo Creo 4 files
example\NX12_brep CMM Scratch from CMM/NX 12 migration Brep Mode
example\NX12_feature CMM Scratch from CMM/NX 12 migration Feature Mode
example\NX1847_Series CMM Scratch from CMM/NX 1847 Series migration Brep Mode
FolderDescriptionTranslation Mode
example_simple\Creo Creo 4 files
example_simple\NX12 CMM Scratch from CMM/NX 12 migration Brep Mode
example_simple\NX1847_Series CMM Scratch from CMM/NX 1847 Series migration Brep Mode The problem "CMM Creo - Pattern Feature unsupportet for Assembly Cut"has been investigated and the following has been found.
Support for the desired pattern features will be considered for a future release of CMM. PR 9478090 Product Information: Product: NX , Application: CMM , Version: V1859