Content Migration Manager > Knowledge base > Pro/ENGINEER and Creo
Duplicated part files when converting Creo to NX.
Duplicated part files when converting Creo to NX. PR Number: 10679476
Priority: 3
Business Urgency: No
GTAC Urgency: No
PR Definition Matrix: INVAL - WRONG_RESULT 6 ab
=======================================================================
Problem Description:
Duplicated part files when converting Creo Parametric to NX.
=======================================================================
Customer NX Version: NX 2007
PLMS Version(s) tested: NX 2007
Managed Mode: No
Tc Version(s): n/a
Env Specific: n/a
O/S Version: Win 1064
Problem is part specific: No
PRDT Contents
Data uploaded in file:
Upload contents:
Part: yes
Movie: no
Syslog: yes
Other Files: yes
======================================================================
Steps to Duplicate:
Migrate Creo files with CMMSolo
Work Around: n/a
Syslog Extract: n/a
Expectation:
.prt files should not be duplicated The problem where cmmSolo is producing duplicate NX files from the migration of ProE family table assemblies when CMM option "Migrate All Top Level Family Table Instances" is set and the user selects to migrate an entire OS folder at once is fixed in CMM2306.
The workaround for earlier NX releases is, when running a migration with CMM option "Migrate All Top Level Family Table Instances" set, do not select folder to migrate but instead select item (top level item) to migrate.
PR 10679476 Product Information: Product: NX , Application: CMM , Version: V2007
Source: https://support.sw.siemens.com/en-US/knowledge-base/PL8713931 · retrieved 2026-10-02