NXKnowledge

Content Migration Manager > Knowledge base > Pro/ENGINEER and Creo

Duplicated part files when converting Creo to NX.

Duplicated part files when converting Creo to NX. PR Number: 10679476

Priority: 3

Business Urgency: No

GTAC Urgency: No

PR Definition Matrix: INVAL - WRONG_RESULT 6 ab

=======================================================================

Problem Description:

Duplicated part files when converting Creo Parametric to NX.

=======================================================================

Customer NX Version: NX 2007

PLMS Version(s) tested: NX 2007

Managed Mode: No

Tc Version(s): n/a

Env Specific: n/a

O/S Version: Win 1064

Problem is part specific: No

PRDT Contents


Data uploaded in file:

Upload contents:

Part: yes

Movie: no

Syslog: yes

Other Files: yes

======================================================================

Steps to Duplicate:

Migrate Creo files with CMMSolo


Work Around: n/a

Syslog Extract: n/a

Expectation:

.prt files should not be duplicated The problem where cmmSolo is producing duplicate NX files from the migration of ProE family table assemblies when CMM option "Migrate All Top Level Family Table Instances" is set and the user selects to migrate an entire OS folder at once is fixed in CMM2306.

The workaround for earlier NX releases is, when running a migration with CMM option "Migrate All Top Level Family Table Instances" set, do not select folder to migrate but instead select item (top level item) to migrate.

PR 10679476 Product Information: Product: NX , Application: CMM , Version: V2007