Weld symbols are out of position when migrated to NX via CMM 7.0
Weld symbols are out of position when migrated to NX via CMM 7.0 Priority: 2
GTAC Urgency: No
PR Matrix: Wrong Results
Problem Description:
Weld symbols on an I-deas drawing migrated to NX have some issues with placement and completeness.
Steps to Duplicate:
An I-deas package file of four parts and their associated drawings is being provided. Also, a Microsoft Word document is being supplied with some sample images in it to illustrate the issues. According to the customer, there are three issues:
The weld symbols on the NX drawing are significantly out of position with
respect to where they were positioned on the NX I-deas drawing.
A couple of the weld symbols in NX I-deas had text - (3x) - appended to them
and that text did not appear on the NX drawing after migration.
Several weld symbols appeared to have multiple leaders on the NX I-deas
drawing that were not present in the NX drawing.
All the above issues are illustrated in the Microsoft Word document that was supplied. In my tests in NX, I came to the following conclusions about these three issues:
The weld symbols when using NX 7.0.1.7 for the migration were not so
significantly out of position in the migrated NX drawing. They were slightly
out of position probably because the weld symbol in NX I-deas presented as a
longer symbol than it did in NX. They WERE slightly out of position, however.
There was still no appended text in the weld symbol when using NX 7.0.1.7 in
the migration process. After migrating the drawing I tried to modify the
weld symbol in NX to include some appended text and could not find a way to
do so in the same manner that NX I-deas could do it. Is this supported? If
so, then this seems to be a bug that still exists.
This is not an issue in any version of the software. Multiple leaders are
not supported for weld symbols in either NX I-deas or NX. What appears to be
weld symbols with multiple leaders is actually one weld symbol with a leader
and one note with no note text. The two were positioned relative to each
other to make it appear that the weld symbol had two leaders. The
positioning change that is occurring with the weld symbol is throwing off
this carefully aligned "fudge" of multiple leaders.
Workaround:
None known for the missing appended text issue. The other two issues require repositioning the weld symbol in NX.
Containing:
Part: Yes
AVI: N/A
Syslog: N/A
Other Files: Yes
Workaround: N/A
User Reproduced In: CMM 7.0, NX 7.0.1.2
GTAC Reproduced In: CMM 7.0.0.157 and NX 7.0.1.7
Managed Mode: No
Tc Versions: N/A
Problem is Part Specific: No
Problem is OS Specific: No
Problem is Platform Specific: No
Problem Verified on following Platforms/OS Versions: Windows
Traceback:
N/A Siemens PLM Software believes that the problem you reported where weld symbols were not migrating with the proper placement and completeness of text will be resolved by code changes made to NX 7.5.4.
PR 1817130 Product Information: Product: NX , Application: TRANSLATOR , Version: V7.0.1
Source: https://support.sw.siemens.com/en-US/knowledge-base/PL8587925 · retrieved 2026-10-02