Content Migration Manager > Knowledge base > I-deas
Views with spaces after the view name will not migrate to NX.
Views with spaces after the view name will not migrate to NX. Description of problem:
I-deas views with spaces at the end of the view name will not migrate to NX using CMM. The following error appears in the NX log file:
Error code 630035 caught in file "D:\workdir\Reference\NX903_4\src\ugplmxmldrawmigr\no\ind\dmm_migrate_view.c" at line number 1789
*** NOTE:: in line 3565 of D:\workdir\Reference\NX903_4\src\ugplmxmldrawmigr\no\ind\dmm_migrate_view.c at Tue Apr 28 14:21:51 2015 Eastern Daylight Time
+++ VIEW: I-deas View, Id = 19: Error raise in create_member_view
*** EXCEPTION: Error code 1515011 in line 226 of o:\ugnx903\ip4\src\syss\no\ind\OM_UserObjectName.cxx at Tue Apr 28 14:21:51 2015 Eastern Daylight Time
+++ Failure trying to set name on Exact (Pre-NX 8.5) Drawing View
How to reproduce the problem:
Import the attached package file.
View the drawing in I-deas and note how views 3,4,and 5 on sheet 5 have spaces after the view name
Migrate the drawing to Nx
Open the migrated drawing and notice how sheet 5 only has 1 view migrated.
Workaround:
Removing the ending space on the view name in I-deas, save the drawing, and then migrate the drawing
Platform(s) and version(s) tested on:
Windows and CMM 10.0.1 and CMM 9.0.3
Data or platform specific:
data
File type:
zip file containing a package file
File location: See coordinator notepad
Other information:
none This issue is currently open and under investigation. When the investigation completes, this article will be updated to include all of the pertinent information and conclusions. If you have further questions related to this article, or any article, please contact Support for assistance. PR 7373709 Product Information: Product: NX , Application: TRANSLATOR , Version: V10.0.1