Content Migration Manager > Knowledge base > I-deas
Lost associativity of Datum Feature when migrate drawing using CMM
Lost associativity of Datum Feature when migrate drawing using CMM Description of problem:
When I create drawing with Datum Feature symbols,and migrate to NX by CMM.
The symbol lost associativity. the problem appears to be independent of the creation method.
CMM report is written following meassage.
The associativity was not completely established for the annotation.
The original I-DEAS annotation was not fully associative or the associativity
could not be re-established during migration. The annotation has been marked retained.
How to reproduce the problem:
In Ideas,create part
Create Datum Feature in Datum(1-3-2)
Check in TDM and export it as pkg
import it in CMM.
execute migration using default cmm option
[CMM]-[Migrate to NX]
- In NX, open this drawing part.
then all of Datum Feature are displayed in a dashed line.
It lost associativity.
Workaround:
Fix in NX
Platform(s) and version(s) tested on:
Windows XP TCUA 2007.1.3, I-deas 6, NX 6.0.1.5, CMM 6.0.1, and TCII 6
Data or platform specific:
data
File type:
Windows zip file containing a package file and a ppt with steps to reproduce.
File location: See coordinator notepad
Other information: Siemens PLM believes that the problem you reported where the assocaitivity of a datum feature was lost will be resolved by code changes made to the upcoming release of our software NX 6.0.5. PR 2110915 Product Information: Product: NX , Application: TRANSLATOR , Version: V6.0.1