Content Migration Manager > Knowledge base > CATIA
CMM Migrating CATIA Drawing to NX - Views and texts are not migrated correctly
CMM Migrating CATIA Drawing to NX - Views and texts are not migrated correctly IR Number: 10338191
Priority: 1
Business Urgency: No
GTAC Urgency: No
PR Matrix: Critical
Problem Description:
================================
Migrating CATIAV5 drawing to NX show up with two serious issues:
1.) Geometric View Content doesn't match
2.) Notes especially in the title block and component table doesn't fit.
Application/Function: CMM CATIAV5 -> Migrate Assembly Drawing to NX
Common/Part specific: common
=============================================================================
Versions:
================================
NX 1946
CATIAV5
CMM 1926
Zip File Containing:
================================
Part: Yes
AVI: no
Syslog: Yes
Other Files: Yes
Steps to Duplicate:
================================
To reproduce within CMMSolo
Migrate CATIA Drawing to NX.
Compare geometric content from "NX Front View" vs, CATIA View
NX-Views.png vs. CATIA-Drawing-Views.png
- Compare title block and component table CATIAV5 vs. NX.
CATIA-Table.png vs. NX-Table.png
CATIA-TitleBlock.png vs. NX-TitleBlock.png
Error:
See log files
Work Around:
================================
Please let us know if there is a Workaround.!
Expectation:
================================
Please investigate the root cause of the Error.
Make sure geometric content and text in NX Drawing View match CATIAV5 Drawing View.
Problem is part specific:
================================
no
Platform Information:
================================
Problem is platform specific: no
Platform: Intel Win10x64-bit
Problem verified on the following platform and OS versions:
Intel Win10x64-bit,
CMM1926 NX1946
Additional Notes:
================================
Please let us know if there is a Workaround.
Siemens Digital Industries Software believes that the reported problem is fixed in CMM 2306.
PR 10338191 Product Information: Product: NX , Application: CMM , Version: V1926