NXKnowledge

Content Migration Manager > Knowledge base > Pro/ENGINEER and Creo

Wrong view boundaries

Wrong view boundaries IR Number: 1985529

       Priority:	2

Business Urgency: No

   GTAC Urgency:	No

      PR Matrix:	Wrong Result

Problem Description:

================================

Wrong view boundaries.

Errors in geometry representation were found on boundaries of NX view.

The incorrect representation of the view boundaries is based on the incorrectly migrated Section View F-F on sheet 3 of the sectional view in NX.

Application project: CMM PROE to NX

Drawing/Design: Drawing

Common/Part specific: common

Function: Section View - Simple/Stepped Section Lines

=============================================================================

Versions:

================================

NX: 8.5.3.3

Managed Mode: No

CMM: 8.5.2.186

1985529_6204983_logs.7z

1985529_IR_15_15_Wrong_view_boundaries.docx.7z

Containing:

================================

1.) All PROE/NX parts and logs (syslog, cmm log, option file, etc.) located in: 1985529_6204983_logs.7z

2.) 1985529_IR_15_15_Wrong_view_boundaries.docx

Work Around:

================================

Unknown

Steps to Duplicate:

================================

  1. CMM PROE drawing - Item ID: 6204983.drw

  2. Compare section View E-E vs. F-F (PROE vs. NX) on sheet 3

See "1985529_IR_15_15_Wrong_view_boundaries.docx" for steps to duplicate and for clarification.

==> ERROR: Missing geometry in Section View

Expectation:

Section View should be created like it was in PROE

Problem is part specific: Unknown

Platform Information:

================================

Problem is platform specific: Unknown

Platform: Intel Win764-bit

Problem verified on the following platforms and OS versions:

Intel Win764-bit, NX 8.5.3.3 / CMM 8.5.2.186 The problem where "Wrong view boundaries" has been closed as No Fix.

We received a note from the customer confirming that Migration from Pro-E to NX is going to be completed in January. For this reason they declare that the PRs are not anymore relevant for the project and they would like that PR 1985529 Product Information: Product: NX , Application: TRANSLATOR , Version: V8.5.2

Source: https://support.sw.siemens.com/en-US/knowledge-base/PL8029931 · retrieved 2026-10-02