Content Migration Manager > Knowledge base > Pro/ENGINEER and Creo
Wrong view boundaries
Wrong view boundaries IR Number: 1985529
Priority: 2
Business Urgency: No
GTAC Urgency: No
PR Matrix: Wrong Result
Problem Description:
================================
Wrong view boundaries.
Errors in geometry representation were found on boundaries of NX view.
The incorrect representation of the view boundaries is based on the incorrectly migrated Section View F-F on sheet 3 of the sectional view in NX.
Application project: CMM PROE to NX
Drawing/Design: Drawing
Common/Part specific: common
Function: Section View - Simple/Stepped Section Lines
=============================================================================
Versions:
================================
NX: 8.5.3.3
Managed Mode: No
CMM: 8.5.2.186
1985529_6204983_logs.7z
1985529_IR_15_15_Wrong_view_boundaries.docx.7z
Containing:
================================
1.) All PROE/NX parts and logs (syslog, cmm log, option file, etc.) located in: 1985529_6204983_logs.7z
2.) 1985529_IR_15_15_Wrong_view_boundaries.docx
Work Around:
================================
Unknown
Steps to Duplicate:
================================
CMM PROE drawing - Item ID: 6204983.drw
Compare section View E-E vs. F-F (PROE vs. NX) on sheet 3
See "1985529_IR_15_15_Wrong_view_boundaries.docx" for steps to duplicate and for clarification.
==> ERROR: Missing geometry in Section View
Expectation:
Section View should be created like it was in PROE
Problem is part specific: Unknown
Platform Information:
================================
Problem is platform specific: Unknown
Platform: Intel Win764-bit
Problem verified on the following platforms and OS versions:
Intel Win764-bit, NX 8.5.3.3 / CMM 8.5.2.186 The problem where "Wrong view boundaries" has been closed as No Fix.
We received a note from the customer confirming that Migration from Pro-E to NX is going to be completed in January. For this reason they declare that the PRs are not anymore relevant for the project and they would like that PR 1985529 Product Information: Product: NX , Application: TRANSLATOR , Version: V8.5.2
Source: https://support.sw.siemens.com/en-US/knowledge-base/PL8029931 · retrieved 2026-10-02