Attributed symbol is incorrectly migrated Description of problem:
Attribute symbol migration is incorrect. The first entry in the table is copied into all cells once the drawing is migrated.
How to reproduce the problem:
Import the attached package files
Migrate the drawings
Compare the drawings in NX and I-deas and notice how the attributed symbol along the right hand side of the drawings is incorrect. The value for the first cell has been copied to the other cells. There are pdf files of the drawings before migration to help show the issue.
Workaround:
None
Platform(s) and version(s) tested on:
CMM 9.0.3 and CMM 10.0.2 - problem appears in both versions
Data or platform specific:
data - although 30% of their drawings have this issue
File type:
zip file containing package files
File location: See coordinator notepad
Other information:
This appears to be the same issue as PRs 7452288, 7429189, 1926170. This is also an issue if an asc file is exported out of I-deas and then imported into NX under the File->Import I-deas ASC/DWG functionality.
Siemens PLM believes that the problem you reported where an attributed symbol is incorrectly migrated will be resolved by code changes made to the release of our product NX version 12 and NX version 11.0.2 mp2.
PR 7635987 Product Information: Product: NX , Application: TRANSLATOR , Version: V9.0.3