Content Migration Manager > Knowledge base > I-deas
CMM I-deas: Fidelity Check Failed
CMM I-deas: Fidelity Check Failed IR Number: 8284223
Priority: 1
Business Urgency: No
GTAC Urgency: No
PR Matrix: Wrong Result
Problem Description:
================================
CMM I-deas: Fidelity Check Failed
Resultant Geometry is different but "Fidelity Check" reported no errors
Common/Part specific: common
Function: Fidelity Check
=============================================================================
Versions:
================================
NX: 9.0.3
CMM 9.0.3.rev1
Managed Mode: YES
Teamcenter 9.1.2.7
Containing:
================================
Part: Yes
AVI: n/a
Syslog: n/a
Other Files: Yes
Work Around:
================================
Unknown
Steps to Duplicate:
================================
Open Model File and check-in part to Teamcenter
Migrate Part with CMM
Migration finishes without reporting any "Error" or "Warning"
But NX geometry is different from the original geometry
Compare NX Extrude70 vs. I-deas Extrude(64)
See attached PDF for steps to duplicate and for clarification.
==> ERROR:
================================
Fidelity Check failed Geometry and Feature check!
Expectation:
================================
Fidelity Check must give a Warning/Error if NX geometry is different from original geometry
Problem is part specific: no
Platform: Intel Win764-bit
Problem verified on the following platforms and OS versions:
Intel Win764-bit, NX10.0.2.6.MP1 and CMM 10.0.
Additional Notes:
================================
The problem where "CMM I-deas: Fidelity Check Failed" has been investigated and the following has been found.
In general, fidelity check detects most of the cases. This case is special where we are unable to detect that the face is not correct. Fidelity Check PR 8284223 Product Information: Product: NX , Application: TRANSLATOR , Version: V9.0.3
Source: https://support.sw.siemens.com/en-US/knowledge-base/PL8058026 · retrieved 2026-10-02