Content Migration Manager > Knowledge base > I-deas
Former Ideas migrated Assemblies will not open in NX 11.02 MP6 or later
Former Ideas migrated Assemblies will not open in NX 11.02 MP6 or later IR Number: 9209019
Priority: 1
Business Urgency: No
GTAC Urgency: No
PR Matrix: Regression, a
Problem Description:
================================
Larger with CMM to NX migrated I-deas Assemblies will not open in NX 11.02 MP6 or later and cause NX to crash.
Small assemblies will open but takes one hour instead of ~20 sec.
The Problem could be reproduced within native NX and within NXMANAGER.
Application/Function: Assemblies / File Open
Common/Part specific: Common
=============================================================================
Versions:
================================
NX 11.0.2.MP6 up to MP10
Managed Mode: YES
Temacenter V11000.2.4.41_20170726.00
Zip File Containing:
================================
Part: Yes
AVI: no
Syslog: Yes
Other Files: no
Steps to Duplicate:
================================
Open assembly "50593863803_001.prt" in NX 11.0.2MP5 it will take just ~20 sec.
Open assembly "50593863803_001.prt" in NX 11.0.2MP6 or later it will take ~3600 sec.
You can reproduce this with NX native and/or within Teamcenter.
==> ERROR: No Error message, but larger Ideas migrated Assemblies cause NX to crash during open.
Work Around:
================================
Unknown
Expectation:
================================
- Please investigate the root cause of the delay loading the assembly and create a Fix for the next MP of NX11
Problem is part specific:
================================
Yes
Platform: Intel Win764-bit
Problem verified on the following platforms and OS versions:
Intel Win764-bit, NX11.0.2.MP5 / NX11.0.2.MP10
Additional Note
================================
This Customer is a former I-deas user and therefor they have a large amount of I-deas assemblies migrated to NX.
All files are already refiled with NX 11.0.0 earlier.
The Problem could be reproduced within native NX and within NXMANAGER.
Siemens PLM believes that the problem you reported where Former Ideasmigrated Assemblies will not open in NX11.0.2MP6 or later will be resolved by code changes made to the release of our product NX12.0.2.
In earlier releases, the problem can be worked around by opening the assembly
In the case of an I-Deas migrated assembly, it may be possible to remove many of the positioning overrides from the assembly, improving performance generally. PR 9209019 Product Information: Product: NX , Application: ASSEMBLIES , Version: V11.0.2
Source: https://support.sw.siemens.com/en-US/knowledge-base/PL8109189 · retrieved 2026-10-02