NXKnowledge

Content Migration Manager > Knowledge base > Pro/ENGINEER and Creo

CMM Report error in Max Deviation.

CMM Report error in Max Deviation. PR Number:   11237608

Priority:   2

Business Urgency:   No

GTAC Urgency:   No

PR Matrix:   6a

=======================================================================

Problem Description:

CMM Report shows 'Item Fidelity-Success'.

However, when using Body Compare in NX, the max deviation is greater than 'Maximum deviation for success criteria'.

=======================================================================

Customer NX Version: NX2312.8500

PLMS Version(s) tested:

Managed Mode: No

Tc Version(s):n/a

Env Specific:  n/a

Problem is part specific:   Unknown

PRDT Contents


Data uploaded in file: 11237608.7z

Upload contents:

Part:      Yes

Movie:      n/a

Syslog:      n/a

Other Files:   Yes

======================================================================

NX : NX 2312.8500

CMM : CMM2312

Creo : 7.0.3.0

Steps to Duplicate:

CMM Report shows 'Item Fidelity-Success' but when using Body Compare in NX the max deviation is greater than 'Maximum deviation for success criteria'.

Please refer to the attached ppt and sample parts for more details.


Work Around:   n/a

Syslog Extract:  n/a The problem where "CMM Report error in Max Deviation." has been investigated and the following has been found.

Siemens Digital Industries Software believes that the problem you reported where the CMM migration report shows 'Item Fidelity-Success' is working as intended since this migration report is reporting the results of the comparison method that is available through the "Check Feature Fidelity" command which is found within the "Migrated Item" tab in the "Displayed Part Properties" window (right mouse click on part in Assembly Navigator to get to this window). This "Check Feature Fidelity" command compares the "on Screen" body you see with the hidden body that was extracted from Source CAD and stored in the NX model and this comparison shows no diffs for this part.

As reported in this PR, the Compare Body found within "Analysis" in NX produces a difference in its results. However, this Compare Body uses extracted resultant geometry and so this is a different comparison from the one used by the "Check Feature Fidelity" command.

PR 11237608 Product Information: Product: NX , Application: CMM , Version: V2312.8500

Source: https://support.sw.siemens.com/en-US/knowledge-base/PL8837445 · retrieved 2026-10-02