NXKnowledge

Content Migration Manager > Knowledge base > Pro/ENGINEER and Creo

CMM: Components are not placed in Assembly

CMM: Components are not placed in Assembly IR Number:     9533206

          Priority:     1

  Business Urgency:     No

      GTAC Urgency:     No

         PR Matrix:     Wrong Result

Problem Description:

================================

                         

Assembly BOM structure from CMM PROE will incorrect displayed and migrated after loaded in CMM from a local folder. The issue is not reproduceable accessing the same data from a mapped drive.

Application/Function: CMM Proengineer -> File Open PROE assembly

Common/Part specific: Unknown

=============================================================================

Versions:

================================

NX 12.0.2

PROE/CREO03 140

CMM 12.0.2

               

Zip File Containing:                    

================================          

Part:          Yes

AVI:          no

Syslog:          Yes

Other Files:     Yes

Steps to Duplicate:

================================

  1. The issue is only if you copy the data to a local folder! From a mapped drive the migration works fine.

  2. With CMM open ASM de60-1200-1z18_5_we_spitze

  3. In Creo de60-1200-1z18_5_we_spitze is the Top Item, but CMM list the REC214_REC215 as the top item (see CREO_Baum.png).

  4. Migrating with features or brep will end up with wrong results

See image for details and how to reproduce.

               

==> ERROR:

Assembly structure wrong created in CMM if accessed from a local drive.

Work Around:

================================

unknown

          

Expectation:

================================

Please investigate the root cause of the mismatch.     

Make sure structure will match as in PROE

     

Problem is part specific:

================================

unknown

Platform Information:

================================

Problem is platform specific:     no

 

Platform:    Intel Win10x64-bit

Problem verified on the following platform and OS versions:

Intel Win10x64-bit,

CMM12.0.2.1 NX12.0.2MP9, CREO3/M120

Additional Notes:

================================

Siemens Digital Industries Software believes that the reported problem is fixed in CMM 2306.

PR 9533206 Product Information: Product: NX , Application: CMM , Version: V12.0.2

Source: https://support.sw.siemens.com/en-US/knowledge-base/PL8126287 · retrieved 2026-10-02