Content Migration Manager > Knowledge base > Pro/ENGINEER and Creo
CMM: Components are not placed in Assembly
CMM: Components are not placed in Assembly IR Number: 9533206
Priority: 1
Business Urgency: No
GTAC Urgency: No
PR Matrix: Wrong Result
Problem Description:
================================
Assembly BOM structure from CMM PROE will incorrect displayed and migrated after loaded in CMM from a local folder. The issue is not reproduceable accessing the same data from a mapped drive.
Application/Function: CMM Proengineer -> File Open PROE assembly
Common/Part specific: Unknown
=============================================================================
Versions:
================================
NX 12.0.2
PROE/CREO03 140
CMM 12.0.2
Zip File Containing:
================================
Part: Yes
AVI: no
Syslog: Yes
Other Files: Yes
Steps to Duplicate:
================================
The issue is only if you copy the data to a local folder! From a mapped drive the migration works fine.
With CMM open ASM de60-1200-1z18_5_we_spitze
In Creo de60-1200-1z18_5_we_spitze is the Top Item, but CMM list the REC214_REC215 as the top item (see CREO_Baum.png).
Migrating with features or brep will end up with wrong results
See image for details and how to reproduce.
==> ERROR:
Assembly structure wrong created in CMM if accessed from a local drive.
Work Around:
================================
unknown
Expectation:
================================
Please investigate the root cause of the mismatch.
Make sure structure will match as in PROE
Problem is part specific:
================================
unknown
Platform Information:
================================
Problem is platform specific: no
Platform: Intel Win10x64-bit
Problem verified on the following platform and OS versions:
Intel Win10x64-bit,
CMM12.0.2.1 NX12.0.2MP9, CREO3/M120
Additional Notes:
================================
Siemens Digital Industries Software believes that the reported problem is fixed in CMM 2306.
PR 9533206 Product Information: Product: NX , Application: CMM , Version: V12.0.2