NXKnowledge

Content Migration Manager > Knowledge base > Pro/ENGINEER and Creo

CMM Proengineer issue

CMM Proengineer issue

	  IR Number:	9180914

   Priority:	2

 GTAC Urgency:	No

  PR Matrix:	

============================

Problem Description: CMM Proengineer issue

=============================================================================

NX Versions: CMM Version 10.0.3.106 build 03/21/2016

Managed Mode: No

Tc Versions: N/A

Containing:


Part: 9180914_CADFILESBATCH_23.zip

AVI: n/A

Syslog: n/a

Other Files: 9180914_CMM_data.7z

Work Around: n/a

Steps to Duplicate:

-Convert the part files in 9180914_CADFILESBATCH_23.zip using CMM 10.0.3.106.

This is the specific version Customer is using today in France.

Screenshots of the errors can be seen in the activity ID 102155599

-The logs are in 9180914_CMM_data.7z

This is the problem.

See *.avi for steps to duplicate and for clarification.

Problem is part specific: Unknown

Problem is OS specific: Unknown

Platform Information-

Problem is platform specific: Unknown

Platform:

Problem verified on the following platforms and OS versions:

 Win7 64-bit

The problem where there was a CMM Proengineer issue has been investigated and the following has been found:

The issue with selecting the folder is caused by looping product structure relationships. This is the same as ER 7426077. The enhancement to resolve to CMM 11.0.1, please select the top level item rather than the folder for migration.

PR 9180914 Product Information: Product: NX , Application: CMM , Version: V10.0.3

Source: https://support.sw.siemens.com/en-US/knowledge-base/PL8107510 · retrieved 2026-10-02