Content Migration Manager > Knowledge base > I-deas
Error during CMM migration of 2D drawing.
Error during CMM migration of 2D drawing. Description of problem:
Migration of a standalone drawing fails with the following error:
NXClient.importIDEASPart
*** 2018-01-23 13:07:17.922 System error during part import
Failed to import XPK
drawing: 1267-084-0096/A-1267-084_0096 exported 90%
*** 2018-01-23 13:07:17.922 Failed to create NX part
getCMMSessionFormData
How to reproduce the problem:
- Run CMM on the attached package file
Workaround:
There are two notes in the drawing on view 3 that seem to be causing the problem. There is a picture that shows which notes. If these are deleted, the drawing will migrate. You can also export an asc and open it in NX to get around the issue.
Platform(s) and version(s) tested on:
CMM11 and NX11
Data or platform specific:
data specific
File type:
package file of drawing, cmmscratch directory, and a picture of the issue
File location: See coordinator notepad
Other information:
none This issue is currently open and under investigation. When the investigation completes, this article will be updated to include all of the pertinent information and conclusions. If you have further questions related to this article, or any article, please contact Support for assistance. PR 9044704 Product Information: Product: NX , Application: TRANSLATOR , Version: V11.0.2