Text from Surface Finish Symbol not created

Text from Surface Finish Symbol not created IR Number : 8314613

Priority : 2

Business Urgency : No

GTAC Urgency : No

PR Matrix : Wrong Result

===========================================================================

Problem Description:

If loading drawings the Text from Surface Finish Symbol is not created.

===========================================================================

Material:

  • POWERPOINT

  • SYSLOGFILES

  • PARTS

  • TEXTFILES

===========================================================================

Versions:

NX 11.0.0.33

Managed Mode: No

===========================================================================

Containing:

8314613_74306b97-7b3f-11e6-802b-dd5e64b738b1.zip

===========================================================================

Steps to Duplicate:

  1. open NXM11 (NX-Migration)

  2. load a CATDrawing

  3. start the migration in NXM11

  4. load the migrated NX-File (Drawing) in NX11

Error:

text from surface finish symbol are not created

Expectation:

Text from Surface Finish Symbol should be created

===========================================================================

Work Around: Unknown

Problem is part specific: Unknown

Platform Information:

Problem is platform specific: Unknown

Platform: Intel Win764-bit

Problem verified on the following platforms and OS versions:

Intel Win764-bit, NX 11.0.0.33

===========================================================================

Additional Notes:

Text from Surface Finish Symbol not created Siemens PLM believes that the problem you reported "Text from SurfaceFinish Symbol not created" will be resolved by code changes made to the release of our product CMM11.0.2. PR 8314613 Product Information: Product: NX , Application: CMM , Version: V11.0