NXKnowledge

Content Migration Manager > Knowledge base > I-deas

Problem of View Label in I-deas data with CMM.

Problem of View Label in I-deas data with CMM. PR Number: 2231605

Priority: 2

GTAC Urgency: No

PR Matrix: 6a.

============================

Problem Description:

Problem of View Label in I-deas data with CMM.

=============================================================================

NX Versions: NX8.5.2.3,NX9MP1

CMM Versions: CMM8.5.2

Managed Mode: No

Tc Versions: n/a

Containing:


Part: Yes

AVI: Yes

Syslog: n/a

Other Files: Yes

Work Around: n/a

Steps to Duplicate:


  1. Open attached part file named ID-draw2.1.prt

    (This data already migrated from I-deas with CMM.)

  2. Edit the Section Line and move the segment.

    -> View Label is display.

In NX8.5.2, View Label is display from above steps, and the "Display Label" option is OFF.

In NX8.5.3, View Label is display and "Display Label" option is ON.

IN NX9 View Label is display from above steps, and the "Display Letter" option is OFF.


Trace Back:

N/A:

Problem is part specific: Unknown

Problem is OS specific: Unknown

Platform Information-


Problem is platform specific: Unknown Platform:

Problem verified on the following platforms and OS versions:

NX Versions Tested In GTAC: NX8.5.2.3,NX9MP1

CMM Versions: CMM8.5.2

OS Versions used during Test: Intel Win 7 64Bit

Siemens PLM believes that the problem you reported where 'Problem of View Label in I-deas data with CMM' will be resolved by code changes made to the upcoming release of our software NX10.

PR 2231605 Product Information: Product: NX , Application: DRAFTING , Version: V8.5.2