Content Migration Manager > Knowledge base > General (install, licensing, Teamcenter, batch)
Open/Search times in NX from TcUA not linear across assembly size
Open/Search times in NX from TcUA not linear across assembly size Problem Description:
TcUA 8.3.3.1
NX 8.0.1.5
Win2008 R2 Server for business logic (pool server)
WinXP 64bit for 4 tier client
CMM 8.0.1.203
Open/Search times in NX from TcUA not linear across assembly size
Added the following debug variables:
Set "Generate Support Logs for IR/PR"
Tab for Teamcenter Integration for NX - LOAD and PERFORMANCE
Steps to reproduce:
Note that although we are performing this on 2 assemblies - the small assembly is a sub-assembly of the large, and
the part we search is the same for both cases, and the number of occurences returned in each case is the same.
Login to TcUA
Launch NX
Open assembly (small first, then large)
3a. Structure only
3b. Revision Rule 2
3c. Use Partial Loading
3d. Use Lightweight Representations
From the tree - search part 123X
Select (Open) part and perform "Open by Proximity" - 10"
Log all times
details of question / issue.
The small assembly is approximately 5 times smaller than the large
small = 17460 occurences
large = 103938 occurences
The times to perform the tasks above are not even close to being 5X slower:
Search structure for part: Small: 10 seconds, Large: 160 seconds
Open by Proximity: Small: 1 min large: up to 12 min
We would expect a little longer times for performing some of these tasks - but since we are querying the same part,
assemblies, proximety and receiving the same results they should not be 12-16X longer.
NX and TcUA Logs uploaded
Reference questions that may be necessary:
Is the problem part/assembly specific? YES
Does this behavior occur on all clients? YES
Does this behavior occur for all users? YES
How long has this been occurring? Since migration
Were there any administrative changes/software updates before the issues started occurring? NO Siemens PLM believes that the problem you reported where Open/Search times in NX from Teamcenter are not linear across assembly size will be resolved by code changes made to the upcoming release of our software NX 8.5.2.
PR 6799122 Product Information: Product: NX , Application: ASSEMBLIES , Version: V8.0.1