NXKnowledge

Content Migration Manager > Knowledge base > Pro/ENGINEER and Creo

CMM Creo - Datum Feature Symbol not migrated to NX

CMM Creo - Datum Feature Symbol not migrated to NX 1 Call Information

This call needs to be transferred to GTAC US and marked as PR so that the customer data can be made available to the Milford migration lab people working with CMM Pro/E tools.

2 Symtom / Problem Description

The Datum Feature Symbols (A) are not migrated to NX, or only as text and lines.

2.1 Environment setup:

Environment Setup:

CMM Solo 1872.050

NX 1872 (Build 1500)

Creo Parametric 4.0 - M080

Windows10

2.2 Expectations

We expect the Datum Feature Symbols (A) to be migrated to NX (associative), and can be edited.

2.3 Detail Information

Example 1 (BLH):

Creo: 045_01_bezug_quader.drw.25 (Folder: BLH\Creo)

NX: 045_01_bezug_quader_drw.25.prt (Folder: BLH\NX1872)

Problem: The Datum Feature Symbols (A) marked in red are migrated as text and lines to NX.

Example 2 (BLH):

Creo: 045_02_bezug_rotationskoerper.drw.18 (Folder: BLH\Creo)

NX: 045_02_bezug_rotationskoerper_drw.18.prt (Folder: BLH\NX1872)

Problem: The blue marked Datum Feature Symbols (A) will not be migrated to NX.

Example 3 (MKR):

Creo: bezugssysmbole.drw.23 (Folder: MKR\Creo)

NX: bezugssysmbole_drw.23.prt (Folder: MKR\NX1872)

Problem: The Datum Feature Symbols (A) marked in red are migrated as text and lines to NX. The blue marked Datum Feature Symbols (A) will not be migrated to NX.

Note:

If you need more drawings to investigate please let us know.

2.4 Supporting Data

For more detailed information see PDF document within IR-Data Zipfile

.zip

FolderDescriptionTranslation Mode

BLH\Creo Creo files

BLH\NX1872 CMM Scratch from CMM/NX 1872 Series migration

MKR\Creo Creo files

MKR\NX1872 CMM Scratch from CMM/NX 1872 Series migration

2.5 Plattform

Windows 10

2.6 Platform Specific

no

2.7 Version Specific

no This issue is currently open and under investigation. When the investigation completes, this article will be updated to include all of the pertinent information and conclusions. If you have further questions related to this article, or any article, please contact Support for assistance. PR 9580186 Product Information: Product: NX , Application: CMM , Version: V1872

Source: https://support.sw.siemens.com/en-US/knowledge-base/PL8129130 · retrieved 2026-10-02