CMM Solo Solidworks : Issue with Base Flange translation

CMM Solo Solidworks : Issue with Base Flange translation IR Number:     9387997

          Priority:     1

  Business Urgency:     No

      GTAC Urgency:     No

         PR Matrix:     Wrong Result a, b

Problem Description:

================================

                         

CMM (Content Migration Manager) for SolidWorks

Result of Base Flange definition "Mid Plane" in SoldiWorks will be "Finite" in NX Base Contour Flange Option.

Application/Function: CMM -> SolidWorks

Common/Part specific: Common

=============================================================================

Versions:

================================

Teamcenter -

CMM 12.0.2

NX 12.0.2MP2

Managed Mode:     no

               

Zip File Containing:                    

================================          

Part:          Yes

AVI:          no

Syslog:          no

Other Files:     Yes

Steps to Duplicate:

================================

  1. Migrate SolidWorks Part —1307296~01.SLDPRT™ to NX

       

See pptx for further details.

               

==> ERROR:

Result of Base Flange definition "Mid Plane" in SoldiWorks will be "Finite" in NX Base Contour Flange Option.

Should be "Symmetric"

Work Around:

================================

unknown

          

Expectation:

================================     

Please create a fix for NX12.0.2

     

Problem is part specific:

================================

unknown

Platform Information:

================================

Problem is platform specific:     no

 

Platform:    Intel Win764-bit

Problem verified on the following platform and OS versions:

Intel Win764-bit,

NX12.0.2.MP3, CMM12.0.2

Additional Notes:

================================

Siemens Digital Industries Software believes that the reported problem is fixed in CMM 2306.

PR 9387997 Product Information: Product: NX , Application: CMM , Version: V12.0.2