Problem Description:

Catia ASM with fexible sub assembly write Information regarding flexible Feature in TC BOM.

CMM changed this BOM information during Migration.

After Migration when User open Catia data which have status Released, in Catia, Information regarding Flexible Sub Assembly is lose.

Catia Integration write Information regarding Flexible Component in BOM Line Attribute bl_plmxml_abs_xform.

in Attachment are Scratch Folder and PDF file with some screenshots.

This defect was coordinated with CMM development and recognized as a high priority.

=============================================================================

NX Versions:   NX 1953

Managed Mode:   Yes / No

Tc Versions:   n/a / TC 2007

Containing:


Part:      n/a

AVI:      n/a

Syslog:      n/a

Other Files:   n/a

Work Around:   n/a

Steps to Duplicate: 

unable to duplicate this here in the office due to missing CMM Catia licenses.

Provided data was uploaded to the PRDATA tool.

Problem is part specific:   Yes / No / Unknown

Problem is OS specific:      Yes / No / Unknown

Platform Information-

Problem is platform specific:   Yes / No / Unknown  

Platform:    

Problem verified on the following platforms and OS versions:

Intel IV, Win7 64-bit Siemens Digital Industries Software believes that this PR should be closed as an Enhancement Request.

Customer is not following the recommended NX Migration process which requires a single CAD master.

Recommended practice is that once the Catia data is migrated to NX, then NX should become the new master and any further revisioning should be in NX only.

This is not a general problem, but rather very specific to a customer. There is a high likelihood of unpredictable results when the Catia assembly is allowed to change the BVR in Teamcenter independent of the NX assembly changing the same BVR.

PR 10164265 Product Information: Product: NX , Application: CMM , Version: V1980