NXKnowledge

Content Migration Manager > Knowledge base > I-deas

CMM-Problem: Form- und Lagesymbole Bezugspfeile fehlerhaft

CMM-Problem: Form- und Lagesymbole Bezugspfeile fehlerhaft IR Number: 7949270

       Priority:	1

Business Urgency: No

   GTAC Urgency:	No

      PR Matrix:	Wrong Result

Problem Description:

=============================================================================

CMM I-deas Drawing: All "Multi Segment Leader" sysmbols replaced by the first symbol found during migration.

When a Drawing is migrated to NX that use "Multi Segment Leader", all those symbols will be matched to the "Multi Segment Leader" symbol found first.

=============================================================================

Versions:

=============================================================================

Managed Mode: Yes

NX: 9.0.3.4 MP15

TC: 10.1.2(20140617.00)

TCII 10.1

I-deas: 6.4

CMM: 9.0.3

Containing:

=============================================================================

Part: yes

AVI: no

Syslog: n/a

Other Files: yes

Steps to Duplicate:

=============================================================================

  1. Import the uploaded Ideas package file into TC (Tools - Import - From TDM)

  2. Select the imported Revision and start the CMM Migration

When you compare the result of the migration you can see all "Multi Segment Leader" are replaced with the one found first.

See PPT for details.

Error: All "Multi Segment Leader" symbols will be migrated to the one found first.

Work Around: Unknown

Problem is part specific: Unknown

Platform Information:

=============================================================================

Problem is OS specific: No

Problem is platform specific: No

Platform: Intel Win764-bit

Problem verified on the following platforms and OS versions:

Intel Win764-bit, NX9.0.3.MP15, CMM 9.0.3

Additional Notes:

================================

This is pretty similar to the PR 7956642:

CMM I-deas: Drawing with Symbols and nested Crosshatches in it are wrong after migration.

but with another system symbol type.

Problem still exist using:

NX10.0.3/CMM Version 10.0.3.1r1.029

NX11.0.1/CMM Version 11.0.0.1.087 This issue is currently open and under investigation. When the investigation completes, this article will be updated to include all of the pertinent information and conclusions. If you have further questions related to this article, or any article, please contact Support for assistance. PR 7949270 Product Information: Product: NX , Application: TRANSLATOR , Version: V9.0.2

Source: https://support.sw.siemens.com/en-US/knowledge-base/PL8082769 · retrieved 2026-10-02