Select a dataset for migration and execute the command "Migrate to NX" from the CMM menu, but nothing happend. 

The CMM interface doesn't come up. 

No error message.

Solution The CMM interface failed to start because dynamic port assignment was disabled on this server.  Instead to enable dynamic port assignment you can set a fixed port number, please follow steps to set a fixed port for CMM:  Edit file "cmmOptions.xml" and give a fixed port number, i.e "3115" similar as below: 

D:\Apps\Siemens\CMM\1926\Config\cmmOptions.xml   

Notes and References Selete the following file to be regenerated with the new values. C:\Users<my_user>\AppData\Roaming\cmm\eng\1926\cmmOptions.xml

Hardware/Software Configuration Platform: INTEL OS: windows OS Version: 10_1909 Product: NX Application: CMM Version: V1926 Function: IDEAS

Ref: 001-9953573