Content Migration Manager > Knowledge base > CATIA
CMM: Translated drawing having no link with 3D part
CMM: Translated drawing having no link with 3D part
IR Number : 8286013
Priority : 2
Business Urgency : No
GTAC Urgency : No
PR Matrix : Wrong Result
==============================================================================
Problem Description:
Drawings translated with CMM10.0.2 and NX10.02 are having no links with 3D
model and all the views are coming as fallback sketches.
Drawings translating without link with 3D
==============================================================================
Material:
WORDDOCUMENT
POWERPOINT
PARTS
LOGFILES
==============================================================================
Versions:
NX 10.0.2.6 D1
Managed Mode: No
============================================================================== Containing: 8286013_49d45009-8d18-11e5-837d-d6b1f8e41d55.zip
==============================================================================
Steps to Duplicate:
translate a CATDrawing by CMM10.0.2
See models have no link to 3D
See all views having fallback sketches
==> ERROR: No error message
expectation:
Drawing should have link with 3D part and all the views should be associative to it.
=============================================================================
Work Around: Unknown
Problem is part specific: Unknown
Platform Information:
Problem is platform specific: Unknown
Platform: Intel Win7 64-bit
Problem verified on the following platforms and OS versions:
Intel Win7 64-bit, NX 10.0.2.6 D1 , NX 11.0.0.7
==============================================================================
Additional Notes:
CMM: v10.0.2
NX : 10.0.2.6 Siemens PLM believes that the problem you reported where CMM: Translated drawing having no link with 3D part will be resolved by code changes made to the release of our product NX10.0.3.
Running the migration of this Catia data in CMM 10.0.3 produces a successful
The incoming provided Catia data is out-of-date on the Catia product side, and requires an update on the Catia side. It could have been this mistake on the legacy data handling side that resulting in submitted this IR/PR. PR 8286013 Product Information: Product: NX , Application: TRANSLATOR , Version: V10.0.2