Content Migration Manager > Knowledge base > I-deas
CMM fails when migrating an Ideas drawing to NX
CMM fails when migrating an Ideas drawing to NX
IR Number: 7959226
Priority: 1
Business Urgency: No
GTAC Urgency: No
PR Matrix: 6a,b
============================
Problem Description:
CMM fails when migrating an Ideas drawing to NX
The CMM process fails, with following error, when attempting to migrate an Ideas drawing to NX:
700003: Critical Error: java.net. SocketException: Connection reset
700003: Failed to create NX part
700003: Critical Error: java.net. SocketException: Connection refused: connect
702046: Migrated 0 items with 1 report failures (1 session failures), and 1 item skipped
This issue occurs using CMM 9.0.3 in the customer environment.
(The same result/failure has been reproduced by GTAC using CMM Solo 9.0.3 and 11r1.)
=============================================================================
NX Versions: CMM/NX 9.0.2 and CMM/NX 11r1
Managed Mode: No
Tc Versions: n/a
Containing:
Part: Yes
AVI: n/a
Syslog: Yes
Other Files: Yes
Work Around: None found. (Deleting all the symbols from the drawing allows the drawing to migrate, but a large amount of the geometry on the drawing was contained in symbols, so the resulting NX drawing was of no value. Smashing all the symbol and the purging them from the Ideas drawing did not resolve the issue.)
Steps to Duplicate:
Migrate the standalone drawing '16_22000-2345_06_0062.mdf' contained in the .pkg file of the same name.
CMM process reaches the 70% stage, where it stalls for 10-15 minutes before failing with the following error:
700003: Critical Error: java.net. SocketException: Connection reset
700003: Failed to create NX part
700003: Critical Error: java.net. SocketException: Connection refused: connect
702046: Migrated 0 items with 1 report failures (1 session failures), and 1 item skipped
(No NX part file is created. The customer has a number of drawings that fail to migrate in a similar way.)
Problem is part specific: No
Problem is OS specific: No
Platform Information-
Problem is platform specific: No Platform:
Problem verified on the following platforms and OS versions:
Intel IV, Win7 64-bit
This issue is currently open and under investigation. When the investigation completes, this article will be updated to include all of the pertinent information and conclusions. If you have further questions related to this article, or any article, please contact Support for assistance. PR 7959226 Product Information: Product: NX , Application: TRANSLATOR , Version: V9.0.3