Content Migration Manager > Knowledge base > I-deas
PR\ Cylindrical dimensions have lost their associativity during the Migration..
PR\ Cylindrical dimensions have lost their associativity during the Migration.. IR Number: 1936020
Priority: 3
GTAC Urgency: No
PR Matrix: 3
============================
Problem Description:
Cylindrical dimensions have lost their associativity during the Migration.
=============================================================================
NX Versions: 8.5.1
CMM : 8.5.1
I-DEAS : 6.2
Managed Mode: No
Containing: Please find the related data in 1936020.7z in PR Data tool.
I-deas Data:
...\1936020\Ideas_pkg
11003816_00_0005.mdf
11003816_0004.prt
ecl.pkg
NX Migrated data:
...\1936020\NX_migrated_data_CMM8.0.2
ens_tige_piston_verin_cdm_11003816_00_14_1920580_dwg.prt
tige_verin_coup_masse_--C000025761_9_1920580_part.prt
...\1936020\NX_migrated_data_CMM8.5.1
ens_tige_piston_verin_cdm_11003816_00_14_AnciensPlans_dwg.prt
tige_verin_coup_masse_--C000025761_9_AnciensPlans_part
Word document:
1936020.doc
Steps to Duplicate:
Migrate the ..\1936020\Ideas_pkg\ecl.pkg using CMM8.0.2 and 8.5.1
From I-deas look at I-deas original drawing (11003816_00) it contains linear Dimensions.
The results using CMM 8.0.2:
Please open
\NX_migrated_data_CMM8.0.2\ens_tige_piston_verin_cdm_11003816_00_14_1920580_dwg.prt
The cylindrical dimensions have been migrated keeping the associativity
- The results using CMM 8.5.1
Please open
\NX_migrated_data_CMM8.5.1\ens_tige_piston_verin_cdm_11003816_00_14_AnciensPlans_dwg.prt
The cylindrical dimensions have been migrated but the associativity have been lost (dimensions are dashed and grey)
See 1936020.doc for steps to duplicate and for clarification.
Problem is part specific: No
Problem is OS specific: No
Platform Information-
Problem is platform specific: No
Platform:
Problem verified on the following platforms and OS versions:
Win7 64-bit I-deas 6.2 NX 8.5.1 CMM 8.5.1
The I-deas to NX Migration issue where the cylindrical dimensions have lost their associativity during the Migration has been investigated and the following has been found:This PR has been reviewed by development. Due to the low priority of the problem and the length of time the current behavior has been in the system we day operation as you use the NX product, please contact GTAC to have the pr reopened PR 1936020 Product Information: Product: NX , Application: TRANSLATOR , Version: V8.5.1
Source: https://support.sw.siemens.com/en-US/knowledge-base/PL8115656 · retrieved 2026-10-02