Content Migration Manager > Knowledge base > I-deas
CMM Session failures, when attempting to migrate drawing
CMM Session failures, when attempting to migrate drawing IR Number: 8253813
Priority: 1
Business Urgency: No
GTAC Urgency: No
PR Matrix: Regression
Problem Description:
================================
CMM I-deas failed to migrate Drawing with Datum
Application: CMM I-deas
Common/Part specific: common
=============================================================================
Versions:
================================
Teamcenter 10 (10.1.2(20140617.00)) 64-bit
TCII 10.1
NX Ideas 6.4
NX 9.0.3.4 MP1
CMM 9.0.2.248
8253813.7z Containing:
================================
8253813- customer data with PKG, log files and screenshots
8253813_PKG-CMM7.5 - example data to use with CMM 7.5.5.1 vs. CMM 9.0.2
Steps to Duplicate:
================================
Import the uploaded Ideas package file 0515-560-13-01.pkg into TC
Select the imported Revision ?0515-560-13-01/A;1 - BLOCK BGR D50 QCC DU01.4_500 T-SLOT? and start the Migration Process using CMM 9.0.2
Mirgation ends unexpected with failure
==> ERROR: 701003 Failed to create NX part
701046 Migrated 1 items with 1 report (1session failures), and 1 items skipped.
The problem is the Datum Feature Symbol, see Screenshot "Datum Feature Symbol A.jpg".
See also example data in 8253813_PKG-CMM7.5, migration works with CMM7.5.5.1 but fails with the same error in CMM9.0.2
Work Around:
================================
You can get around the problem by deleting all the Datum Feature Symbols, saving the drawing, and then start the CMM Migration Process again.
This workaround is not very cumbersome.
Expectation:
================================
No error occurs.
Problem is part specific: Unknown
Platform Information:
================================
Problem is platform specific: Unknown
Platform: Intel Win764-bit
Problem verified on the following platforms and OS versions:
Intel Win764-bit, NX 9.0.3.4 D1, NX 9.0.3.4 MP2
Additional Notes:
- This is a regression, please provide a fix for CMM 9.0.2
This issue is currently open and under investigation. When the investigation completes, this article will be updated to include all of the pertinent information and conclusions. If you have further questions related to this article, or any article, please contact Support for assistance. PR 8253813 Product Information: Product: NX , Application: TRANSLATOR , Version: V9.0.3
Source: https://support.sw.siemens.com/en-US/knowledge-base/PL8040405 · retrieved 2026-10-02