CMM 11 remigration part failed
CMM 11 remigration part failed IR Number: 7964154
Priority: 1
Business Urgency: No
GTAC Urgency: No
PR Matrix: Fatal Error
Problem Description:
=============================================================================
CMM I-deas Drawing: Remigration of any part will end unexpected
=============================================================================
Versions:
=============================================================================
Managed Mode: Yes
NX: NX 11.0.0.33
TC: 11.2.3
TCII 11.2.1
I-deas: 6.5
CMM: 11.0.0.1
Containing:
=============================================================================
Part: no
AVI: no
Syslog: yes
Other Files: yes
Steps to Duplicate:
Prerequisite:
If a "c_p_p_author" exist in your license file uncomment each line:
INCREMENT c_p_p_author
ufunc_development
ugopen_plus_plus
Crate a Block in I-deas and migrate it to NX
In CMM Option enable Remigration and migrate the Block again
CMM process will end unexpected if no CPP author license exists
Error: Validation failed for C:\PLM\CMM11\NXService\NXService.exe and no CPP author license exists
Work Around: Unknown
Problem is part specific: Unknown
Platform Information:
=============================================================================
Problem is OS specific: No
Problem is platform specific: No
Platform: Intel Win764-bit
Problem verified on the following platforms and OS versions:
Intel Win764-bit, TC11/N11/CMM11
Additional Notes:
================================
This issue is currently open and under investigation. When the investigation completes, this article will be updated to include all of the pertinent information and conclusions. If you have further questions related to this article, or any article, please contact Support for assistance. PR 7964154 Product Information: Product: NX , Application: CMM , Version: V11.0.1