CMM: View (4-Ansicht) will not created after Migration from Ideas for NX
CMM: View (4-Ansicht) will not created after Migration from Ideas for NX IR Number: 7283316
Priority: 1
Business Urgency: No
GTAC Urgency: No
PR Matrix: Fatal Error
Problem Description:
=============================================================================
CMM I-deas: View (4-Ansicht) will not create after Migration from Ideas for NX.
This is because the View name in Ideas has a trailing space character: "ANSICHT "
=============================================================================
Versions:
=============================================================================
Managed Mode: Yes
NX: 9.0.3.4 MP3
TC: 10.1.2(20140617.00)
TCII 10.1
I-deas: 6.4
CMM: 9.0.2.248
Containing:
=============================================================================
Part: n/a
AVI: n/a
Syslog: n/a
Other Files: yes
Steps to Duplicate:
=============================================================================
Import the uploaded Ideas package file 0728-907-29-00.pkg into TC (Tools - Import - From TDM)
Select the imported Revision 0728-907-29-00/A; - PLATEN LAYOUT and start the CMM Migration Process ( CMM - Migrate to NX)
Error: Because of the trailing space character in View with name "ANSICHT ", the entire View is lost
Work Around:
Rename the View in I-deas and remove the trailing space character.
Customer does not accept this workaround because of the huge number of affected views.
Problem is part specific: No
Platform Information:
=============================================================================
Problem is OS specific: No
Problem is platform specific: No
Platform: Intel Win764-bit
Problem verified on the following platforms and OS versions:
Intel Win764-bit, NX9.0.3.MP4, TC 10.1.2(20140617.00), CMM 9.0.2.248
Additional Notes:
================================
Since the workaround is to cumbersome, the customer expect in CMM 9.0.x This issue is currently open and under investigation. When the investigation completes, this article will be updated to include all of the pertinent information and conclusions. If you have further questions related to this article, or any article, please contact Support for assistance. PR 7283316 Product Information: Product: NX , Application: TRANSLATOR , Version: V9.0.3