NXKnowledge

Content Migration Manager > Knowledge base > I-deas

NX Assemblies with Multi-CAD structure can't be loaded randomly

NX Assemblies with Multi-CAD structure can't be loaded randomly Some assemblies with a Multi-CAD structure randomly can't be opened anymore, if they are opend in NX with the Load Option :

"All Components"

The named object is located in an (former I-DEAS) Sub-Assembly without any UGMasters (based on BOM-View Revisions, TC-Arrangements and JTs).

Error-message in the NX-syslog-file:

*** EXCEPTION: Error code 580001 in line 169 of O:\ugnx853\ip3\src\syss\dman\ind\om_tag_access.c at Tue Nov 18 17:08:37 2014 Mitteleuropäische Zeit

+++ Attribute "supp_exp" not in class "UGS::CONFG_component_data"

Enclosed you will find the NX- and TC-syslog-file

With the Load Option "Structure Only" there is no error-message. After Update-Structure all parts can be loaded sequentially.

Steps to reproduce:

Please make sure TC/NX is configured for Multi-Cad:

In TC add: TC_NX_Foreign_Datasets=DatasetType="DirectModel" NamedReference="JTPART" NamedReferenceFormat="BINARY" NamedReferenceTemplate="jt"

In NX change: Customer Defaults->Teamcenter Integration for NX->General-> Parts without NX datasets= Never

  1. Import the I-deas PKG data into Teamcenter

  2. Create a new NX assembly and add the top I-deas assembly "12345678EDD-008/3;1-EOI_Assembly" to it.

  3. Save NX assembly to TC

  4. Use CMM to migrate subassembly "SH0001286114-CMMAssy"

After the CMMAssy wwas migrated the NX assembly will no longer load in NX:

Snip from syslog:

&MACRO MESSAGE_BOX -2, The following error occurred during update:

&MACRO MESSAGE_TEXT

&MACRO MESSAGE_TEXT Internal error: an attempt was made to access an attribute not in the relevant class

&MACRO MESSAGE_TEXT

&MACRO MESSAGE_TEXT This was caused while updating an object of type Component

&MACRO MESSAGE_TEXT in part 000588/A.

&MACRO MESSAGE_TEXT This object is a component member with prototype

&MACRO MESSAGE_TEXT in part SH0001286111/3.

Load failed "%UGMGR=V3.2 PH=pFQRJMVHoB2RgA PRH=JidRJMVHoB2RgA PN=000588 PRN=A RT="has shape" AT="UG master part file" ": CPU time: 4.321 secs, Real time: 13.806 secs

&MACRO FOCUS CHANGE IN 1

&MACRO MESSAGE_BOX -2, Could not open 000588/A.

&MACRO MESSAGE_TEXT The following files could not be loaded

&MACRO MESSAGE_TEXT causing this open to fail:

&MACRO MESSAGE_TEXT

&MACRO MESSAGE_TEXT 000588/A - Internal error: an attempt was made to access an attribute not in the relevant class

Please the further details in uploaded log and word documents. Siemens PLM believes that the problem you reported where NX Assemblies with Multi-CAD structure can't be loaded randomly will be resolved by code changes made to the release of our product NX version NX9.0, the next MP of NX8.5 will contain the fix as well.

PR 7236042 Product Information: Product: NX , Application: ASSEMBLIES , Version: V8.5.1