Content Migration Manager > Knowledge base > I-deas
Multiple symbols are replaced by the first symbol in which CMM-solo convert
Multiple symbols are replaced by the first symbol in which CMM-solo convert PR Number: 7519304
Priority: 2
GTAC Urgency: No
PR Matrix: 6a.
============================
Problem Description:
Multiple symbols are replaced by the first symbol in which CMM-solo convert
=============================================================================
NX Versions: NX10.0.2.6
CMM Versions: 10.0.1
Managed Mode: No
Tc Versions: n/a
Containing:
Part: Yes
AVI: n/a
Syslog: n/a
Other Files: Yes
Work Around: Use [Instance Decomposition] command in I-deas to decomposite all the symbols before migration.
Steps to Duplicate:
Run CMM-Solo,Open the file ALPHA.pkg(Which has uploaded to /gtac)
Do the below settings:
a)MigrationOptions -> Cintent Migration -> Geometry -> Feature History ="OFF"
b)MigrationOptions -> Cintent Migration -> Geometry -> Drawing -> Options ="Associative"
3.CMM -> Migrate to NX.
4.Open the Converted file"5CA_DWG.1.prt"
In Drawing View:Multiple symbols as below:
Symbol(2):SECTION LINE M
Symbol(3):SECTION LINE P
Symbol(4):SECTION LINE Q
Symbol(5):Cross Patch (SPRING AREA)
have replaced by Symbol(1):SECTION LINE N .
Trace Back:
N/A:
Problem is part specific: Unknown
Problem is OS specific: Unknown
Platform Information-
Problem is platform specific: Unknown Platform:
Problem verified on the following platforms and OS versions:
NX Versions Tested In GTAC: NX10.0.2.6
OS Versions used during Test: Intel Win 7 64Bit This issue is currently open and under investigation. When the investigation completes, this article will be updated to include all of the pertinent information and conclusions. If you have further questions related to this article, or any article, please contact Support for assistance. PR 7519304 Product Information: Product: NX , Application: TRANSLATOR , Version: V9.0.2
Source: https://support.sw.siemens.com/en-US/knowledge-base/PL8056852 · retrieved 2026-10-02