Content Migration Manager > Knowledge base > Pro/ENGINEER and Creo
CMM Lost BOM of ProE assembly after CMM migration crashes
CMM Lost BOM of ProE assembly after CMM migration crashes IR Number: 7263611
Priority: 1
Business Urgency: No
GTAC Urgency: No
PR Matrix: Fatal Error
Problem Description:
================================
CMM Lost BOM of ProE assembly after CMM migration crashes
Assembly structure (BOM) is lost when CMM crashes at 70 percent. Either it is top level assembly structure, or structure of subassembly.
Application project: CMM PROE to NX
Assembly: BOM structure
Common/Part specific: common
Function: create BOM
=============================================================================
Versions:
================================
NX: 8.5.2.3
ProEngineer WF4 M220 64 bit
CMM 8.5.2.1.047
Managed Mode: YES
Teamcenter 9.1.2.7
Containing:
================================
Part: Yes
AVI: n/a
Syslog: yes
Other Files: yes
Work Around:
================================
Unknown
Steps to Duplicate:
================================
Use attached ProE data to migrate whole assembly level by level with bottom-up approach. Start with parts, then continue with assemblies on deepest level up to top level. Always migrate only assemblies on the same level together. Problem should occur when migrating top level assembly.
See attached MS Word file for steps to duplicate and for clarification.
==> ERROR:
================================
See attached MS Word file
Expectation:
================================
If this deletion of BOM lines cannot be prevented (due to the nature of CMM processing), CMM should be able to reconstruct BOM exactly as it does for Ideas migration when the migration is started. This would eliminate the need of identifying problematic assemblies, opening them in ProE and resaving them to recreate the BOM (this is often time consuming and prevents us from migration).
Problem is part specific: no
Platform: Intel Win764-bit
Problem verified on the following platforms and OS versions:
Intel Win764-bit, NX8.5.2.3
Additional Notes:
================================
BOM is an essential part of every ProE Assembly. It defines the structure of assembly.
Loosing this information leads to restore operations and time consuming actions.
The problem where "CMM Lost BOM of ProE assembly after CMM migration crashes" has been investigated and the following has been found.We have not been able to reproduce this issue. We have not received a response to our request for more information on how to reproduce this. When we receive this information we will consider this enhancement request.
PR 7263611 Product Information: Product: NX , Application: CMM , Version: V8.5.1