NXKnowledge

Content Migration Manager > Knowledge base > General (install, licensing, Teamcenter, batch)

Face Blend Creation failed

Face Blend Creation failed IR Number: 10193503

      Priority:   1

Business Urgency: No

  GTAC Urgency:   No

     PR Matrix:   Critical

Problem Description:

================================

Migrating SW Two-Face Fillet and/or Three-Face Fillet results in a B-Rep in NX.

Application/Function: CMM SW2019 -> Migrate SW Feature to NX

Common/Part specific: common

=============================================================================

Versions:

================================

NX 1953

SW2019

CMM 1953

Zip File Containing:

================================

Part: Yes

AVI: no

Syslog: Yes

Other Files: Yes

Steps to Duplicate:

================================

To reproduce within CMMSolo

  1. Migrate SW Part 1046605~02.SLDPRT.

  2. All Two-/Three-Face Fillets failed to build.

Error:

oFeature Type: Fillet

oVerrundung2: Failed to build

oVerrundung2: Recovered by advanced fall back B-rep

Please see PDF for details and how to reproduce.

Work Around:

================================

unknown

Expectation:

================================

Please investigate the root cause of the Error.

Make sure SW Feature Two-Face Fillet and/or Three-Face Fillet will create corresponding Face Blend Feature in NX.

Problem is part specific:

================================

no

Platform Information:

================================

Problem is platform specific: no

Platform: Intel Win10x64-bit

Problem verified on the following platform and OS versions:

Intel Win10x64-bit,

CMM1953 NX1953 SW2019

Additional Notes:

================================

This issue is currently open and under investigation. When the investigation completes, this article will be updated to include all of the pertinent information and conclusions. If you have further questions related to this article, or any article, please contact Support for assistance. PR 10193503 Product Information: Product: NX , Application: CMM , Version: V1953