NXKnowledge

Content Migration Manager > Knowledge base > General (install, licensing, Teamcenter, batch)

top level configurations ONE/ALL results in different naming and referencing

top level configurations ONE/ALL results in different naming and referencing   IR Number:         10172780 

           Priority:  1

   Business Urgency:      No

       GTAC Urgency:      No

          PR Matrix:            Critical

Problem Description:

================================

The NX files get different suffixes, depending on the 'Migrate ALL Top Level Configurations' or Migrate 'ONE Top Level Configurations' option is turned on.

Reuse of components is not possible if different settings are used during the migration process.

The aim is to use both options during a CAD migration with CMM Solo.

Application/Function: CMM SW2019 -> Migrate SW Assembly to NX

Common/Part specific: common

=============================================================================

Versions:

================================

NX 1953

SW2019

CMM 1953

Zip File Containing:                                              

================================                         

Part:                   Yes

AVI:                   no

Syslog:              Yes

Other Files:       Yes

Steps to Duplicate:

================================

To reproduce within CMMSolo

Migrate SWORKS Assembly with CMM option Migrate ONE Top Level Configurations'

Again migrate SWORKS Assembly with CMM option 'Migrate ALL Top Level Configurations'

Compare result:

1.      Notify different part naming which is unexpected

2.      Notify drawing is referencing sheet metal flat pattern which is unexpected

Work Around:

================================

unknown

Expectation:

================================

Please investigate the root cause of the mismatch.         

Make sure part naming and referencing is the same for 'Migrate ONE Top Level Configurations' and 'Migrate ALL Top Level Configurations'

Problem is part specific:

================================

no

Platform Information:

================================

Problem is platform specific:      no

Platform:    Intel Win10x64-bit

Problem verified on the following platform and OS versions:

Intel Win10x64-bit,

CMM1953 NX1953 SW2019

Additional Notes:

================================

This issue is currently open and under investigation. When the investigation completes, this article will be updated to include all of the pertinent information and conclusions. If you have further questions related to this article, or any article, please contact Support for assistance. PR 10172780 Product Information: Product: NX , Application: CMM , Version: V1953

Source: https://support.sw.siemens.com/en-US/knowledge-base/PL8577541 · retrieved 2026-10-02